What is the minimum size of branch circuit for a bathroom?

What is the minimum size of branch circuit for a bathroom?

20-amp
One 20-amp branch circuit is required for bathrooms in dwelling units.

What is code for outlets in bathroom?

The NEC requires that all outlet receptacles in a bathroom be GFCI protected. Outlet circuit must be 20 amps: The outlets in a bathroom should be served by a 20-amp circuit, separate from the lighting circuit, to provide power items such as curling irons, razors, and hairdryers.

Can a fused spur go in a bathroom?

Spurs / Cable connection units Electrical equipment in a bathroom will generally need to be via a permanent “hard wired” connection. Typically to a cable outlet unit (switched or otherwise), or a fused spur unit (again, switched or otherwise).

How many receptacles can a bathroom branch circuit feed?

If the homeowner had three of these bathrooms and all were of similar design, the 20-amp branch circuit could feed all nine receptacles. In sum, regardless of the number of bathrooms in the home, the one 20-amp branch circuit required in 210.11 (C) (3) could feed all their combined receptacles.

Where is the bathroom branch circuit in NEC?

If the home was equipped with one bathroom containing a countertop receptacle to serve the sink area, and two more receptacles located near the floor on the opposite wall, then the 20-amp branch circuit specified in 210.11 (C) (3) could feed all three of these receptacles.

How to attach a new bathroom to existing plumbing?

The usual practice is to “T” each supply line in at the closest available location on the main pipe. Keep the hot water branch pipes as short as possible to avoid having to wait for hot water. If your house is old enough to have galvanized steel pipes and they aren’t causing problems, you may not want to replace them.

When to install drain and vent lines in bathroom?

Installing drain and vent lines in your bathroom is a home project that can be completed in a weekend. Before you begin, have your plans approved by an inspector and consider the following: Drain and vent lines must be positioned precisely, so you should install them before the supply pipes.

If the homeowner had three of these bathrooms and all were of similar design, the 20-amp branch circuit could feed all nine receptacles. In sum, regardless of the number of bathrooms in the home, the one 20-amp branch circuit required in 210.11 (C) (3) could feed all their combined receptacles.

If the home was equipped with one bathroom containing a countertop receptacle to serve the sink area, and two more receptacles located near the floor on the opposite wall, then the 20-amp branch circuit specified in 210.11 (C) (3) could feed all three of these receptacles.

The usual practice is to “T” each supply line in at the closest available location on the main pipe. Keep the hot water branch pipes as short as possible to avoid having to wait for hot water. If your house is old enough to have galvanized steel pipes and they aren’t causing problems, you may not want to replace them.

Installing drain and vent lines in your bathroom is a home project that can be completed in a weekend. Before you begin, have your plans approved by an inspector and consider the following: Drain and vent lines must be positioned precisely, so you should install them before the supply pipes.