What causes soft lockout on a furnace?

Defective flame sensors are one of the most common causes of lockouts. If the sensor is faulty or dirty, it won’t be able to detect the flame and the controller will stop the ignition sequence. Most modern furnaces will let you start the furnace two more times before it goes into a lockout.

How to troubleshoot a gas furnace with no heat?

Remove the wires from the pressure switch. On a call for heat, the inducer should start. While the inducer is running, short the wires going to the pressure switch with a jumper. Do not short the pressure switch itself. The furnace should start. Caution: the burners may not burn properly. be ready to pull the power.

What should I do if my furnace inducer does not work?

When there is a call for heat, and the inducer starts, if , after 1-2 minutes, the inducer shuts off and pressure switch code comes on, The pressure switch is not closing. To test this, recycle the furnace. Remove the wires from the pressure switch. On a call for heat, the inducer should start.

Why does my furnace not turn on when the thermostat is on?

If nothing happens when the thermostat is set above the home’s current temperature, the most likely causes are these: The furnace switch (located on or near the furnace, looks like a common light switch) is turned off and simply needs to be turned on, though the furnace might have a short delay before starting.

What causes a gas furnace to need repair?

Some of the most common problems that require gas furnace repair include malfunctioning thermostats, frequent cycling, blowers that continuously run, excessive noise, general lack of maintenance, dirty filters and electric ignition or pilot control problems.

What does it mean when your furnace won’t stay lit?

Probably the most common issue when dealing with a furnace that will not stay lit or ignite consistently is a dirty flame sensor. The flame sensor acts as a communication vehicle with the circuit board and tells it when a flame is lit inside the furnace.

Remove the wires from the pressure switch. On a call for heat, the inducer should start. While the inducer is running, short the wires going to the pressure switch with a jumper. Do not short the pressure switch itself. The furnace should start. Caution: the burners may not burn properly. be ready to pull the power.

When there is a call for heat, and the inducer starts, if , after 1-2 minutes, the inducer shuts off and pressure switch code comes on, The pressure switch is not closing. To test this, recycle the furnace. Remove the wires from the pressure switch. On a call for heat, the inducer should start.

Why is the pilot light on my gas furnace not working?

Any blockage in the pilot tube will cause the furnace to not stay lit. So cleaning it is an easy solution without having to replace any parts. Once cleaned out, put everything back in place and test out the furnace. You may need to replace the thermocouple on your gas furnace.