How do you troubleshoot a broken furnace?

  1. 1.) Check the Circuit Breaker Panel for a Tripped Circuit.
  2. 2.) Inspect the Electronic Ignition System or Pilot Light.
  3. 3.) Check the Safety Switch of the Furnace.
  4. 4.) Inspect the Flames Produced By the Burners.
  5. 5.) Inspect the Furnace Limit Switch.
  6. 6.)
  7. 7.)
  8. Reliable Furnace Repair, Tune-Up, & Installation Services.

Can a broken furnace make you sick?

Older heating systems can have problems such as faulty furnaces that may be adding to your sickness and posing a carbon monoxide poisoning threat. Furthermore, gas furnaces create nitrogen dioxide, which can cause asthma in children.

How do I know if my furnace is broken?

Four Signs Your Furnace is Broken

  1. Your Carbon Monoxide Detector Keeps Going Off.
  2. Your House is Not Warm Enough.
  3. Your Heating Bill Suddenly Goes Up.
  4. Your Hear Banging or Gurgling Noises.

How dangerous are furnaces?

Furnaces Are The Most Likely Source for Deadly Carbon Monoxide Gas. Carbon monoxide is an invisible and scentless killer that kills dozens of people every year. Your furnace is one of the top sources for this deadly gas. While a working, tuned furnace won’t cause this problem, a malfunctioning one could.

What to do if your forced air furnace is not working?

For heat pump problems, see Heat Pump Troubleshooting & Repairs. Though forced-air furnaces are normally quite reliable, they can break down. To avoid break downs, it pays to know how to maintain your furnace and fix it when something goes wrong.

How to troubleshoot your home furnace blower problems?

Before you do anything else, eliminate power as the culprit when troubleshooting your home furnace blower problems. Check the setting on the thermostat. The fan must be on at the thermostat for it to operate. Adjust the setting to “Fan” or “Auto.” When you select “On,” the fan stays on even when the heat is off.

Is it dangerous to have a broken furnace heat exchanger?

A damaged heat exchanger in a gas furnace is potentially dangerous to a home’s occupants and should not be ignored. Broken and leaking heat exchangers are responsible for about 1,500 deaths per year in the United States, and many more people are poisoned by exposure to toxic gasses that go unfiltered by defective heat exchangers.

What are the symptoms of a cracked furnace?

This odor alone can cause severe headaches and other physical symptoms in humans. If you smell a formaldehyde-like odor, you should immediately call a professional for a furnace inspection. Combustion gases leaking from a cracked heat exchanger can cause frequent headaches as well as flu-like symptoms.

What should I do if my furnace is not working?

Make sure you properly secure the access panel. After verifying that your furnace filter is clean and installed properly, check the thermostat. Make sure it is set to “heat” and try setting the temperature at least 5 degrees higher than the current room temperature. If the thermostat needs new batteries, replace them.

Can a broken thermostat cause a furnace to not come on?

A broken thermostat can leave you cold. If your furnace won’t come on even though the house is cold, the problem could be a faulty thermostat. The thermostat measures the temperature in your home and directs your furnace to come on when the temperature falls to the level you’ve set.

What happens when an ignitor goes bad in a furnace?

Instead, these ignitors heat up and touch the surface of the gas to heat the air blowing from the furnace. No matter which type of ignitor is in your furnace, this chain of events lights your heater so that it blows hot air. Don’t worry—an ignitor that goes bad is common for most furnaces.

Why does my furnace keep Tripping the breaker?

We mentioned checking the furnace breaker to make sure it’s on. However, if your furnace keeps tripping the breaker soon after it starts blowing air, the culprit could be a faulty ignitor. Repeatedly tripping the breaker is bad for your furnace and your home’s electrical system.