How do you pressure test a fire hose?

How do you pressure test a fire hose?

With the test cap open, the pressure shall be raised gradually to 45 +/- 5 psi allowing all air to be removed from the system. Close the test cap slowly as well as the outlet water supply valve. Secure the hose directly behind the test cap to avoid whipping or other uncontrolled reacting in the event of a hose burst.

What is the hydro testing pressure for fire hose?

10 HYDROSTATIC PROOF PRESSURE TEST Each hose length shall be subjected to an internal hydraulic pressure of 3.43 MPa (35 kgf/cm2) in accordance with 8.3 of IS 443, increasing the pressure at the rate of not exceeding 1 MPa (10.2 kg/cm2) per min and retaining it for one min.

What is the recommended pressure a new hose assembly should be tested to?

The following are recommended guidelines regarding the maximum working pressure: Water Hose up to 150 psi – 3:1 ratio. Hydraulic Hose for all other liquids, solid materials suspended in liquids or air, and water hose over 150 psi – 4:1 ratio.

What is the maximum pressure of a fire hose?

Service test pressures for hose are approximately 110% of its operating pressure. Forestry hose has a normal maximum operating pressure of 275 psi. Attack hose is a flexible hose used to bring water from the fire pumper to a firefighting nozzle to combat municipal fires. The diameters range from 1.5 in. to 3 in.

How much pressure is in a fire hose?

To fight a fire on the ground, a fire hose needs about 150 pounds per square inch of water pressure. To get water to the 30th floor of a building, the pressure needs to be about 300 PSI to offset the effects of elevation.

How many feet of hose are tested at once?

STEP 1: Connect a pumper to a hydrant or other water source. STEP 2: Lay out hose to be tested in lengths not to exceed 300 feet. The number of lines to be tested at one time is limited to the number of discharge outlets on the pumper. Make sure the lines are laid straight without kinks or twists.

How long do you pressure test fire hose?

3 minutes
After the stabilization period, the hose test layout shall hold the service test pressure for 3 minutes without further pressure boosts. If the inspecting personnel walk the test layout to inspect for leaks, they shall be at least 15 ft (4.5 m) to the left side of the nearest hose line in the test layout.

What is hard suction hose most commonly used for?

A hard suction hose is a special type of supply hose that is used to draft water from a static source, such as a river, lake, or portable drafting basin. It is designed to remain rigid and will not collapse when a vacuum is created in the hose to draft the water into the pump.

What are the three types of flexible hose?

Stainless Flexible Hoses (ss flex hose) can be categorized into 3 main pitch types in conformity with their intended uses: Wide, Standard and Closed (Compressed).

How do you inspect a hose?

Inspect cover for cuts, gouges, worn spots or any other condition that exposes the reinforcement. Inspect cover for smashed, kinked, bulges, blisters or soft spots. Inspect hose for 18” behind each coupling for any evidence of leaking, basketing, kinking, bulges, soft spots or cover cracking exposing the reinforcement.

How long does it take to test a fire hose?

Using a hose testing machine or fire department apparatus, raise hose pressure slowly to 45 psi and bleed off air, then raise pressure slowly until the service test pressure is attained and maintained for 3 minutes.* *This is description is only an overview of the process and not intended to fully detail testing.

Which is the best fire hose test pump?

The FH10-H fire hose tester, a gas powered hydrostatic test pump offering 10 GPM up to 450 PSI. Designed to safely test fire hose up to 6″ in diameter.

How does the rice hydro fire hose tester work?

NO WILD LINES – unique to the RICE Hydro line of fire hose testers, a ballvalve strategically placed on the inlet piping allows the user to fill with “LARGE VOLUME at LOW PRESSURE” and test with “LOW VOLUME at… The EL-FHT fire hose tester, an electric powered hydrostatic test pump offering 3 GPM up to 500 PSI.

What do you need for a pressure test?

 Pressure Systems: Pressure Test Plan Form (SLAC-I-730-0A21J-044). A detailed pressure test plan is required for every pressure test conducted at the laboratory. An approved plan may be used for several similar tests.  Pressure Systems: Pressure Test Record Form (SLAC-I-730-0A21J-045).

How to test the pressure of a fire hose?

Connect a nozzle or shutoff device to the end of the hose. The appliance should be secured to prevent an uncontrolled reaction in the event of a hose rupture. 5. Fill the hose-line to be tested with water and bleed off all air. 6. Close the nozzle and increase the pressure to 50 psi. Check for leakage. Tighten couplings as necessary.

NO WILD LINES – unique to the RICE Hydro line of fire hose testers, a ballvalve strategically placed on the inlet piping allows the user to fill with “LARGE VOLUME at LOW PRESSURE” and test with “LOW VOLUME at… The EL-FHT fire hose tester, an electric powered hydrostatic test pump offering 3 GPM up to 500 PSI.

Can a stationary pump be used for a hose test?

A test location shall be selected that allows connection of the hose testing apparatus (pressure source) to a water source. A hose testing machine, a stationary pump, or a pump on a fire department apparatus shall be used as a pressure source. For each source,m the proper procedure set forth in this policy shall be followed.

When to do acceptance test on fire hoses?

Ensuring that all new sections of fire hose purchased by the department are designed and constructed in accordance with the provisions of NFPA 1961, Standard on Fire Hose. 2. Conduct an acceptance test on each section of fire hose before it is placed in the hose inventory.